Breaking Units

Breaking Units


Display per page
Sort by
Product no.: 64777/2

Breaking unit, EBG-series for three-phase asynchronous motors

 

Technical data

Supply voltage power section Up to 440V AC, higher
voltages on request
Rated frequence power section 50Hz, 60Hz on request
Supply voltage control unit 230V AC, optional 24V DC,
and 24/110/400V AC
Power consumption control unit 6VA
Breaking time continuously from 0s to 15s
Breaking current continuously adjustable,
max. 2x nominal current
ED at 2x nominal current 20%: 40 breakes/hour
Start contact potential free contact or
24V DC/10mA
Insulating strenght to power unit 2,5kV
Ambient temperature 0°C to +55°C
Storage temperature -25°C to +85°C
Protection class IP00
Ouput relay Motor/Alarm/Ready 4A/250V AC
Initiator (Option Lin-Br) NPN / PNP, 24V/12mA


Longer breaking times on request.

578.00 *
Product no.: 64783/2

Breaking unit, EBG-series for three-phase asynchronous motors

 

Technical data

Supply voltage power section Up to 440V AC, higher
voltages on request
Rated frequence power section 50Hz, 60Hz on request
Supply voltage control unit 230V AC, optional 24V DC,
and 24/110/400V AC
Power consumption control unit 6VA
Breaking time continuously from 0s to 15s
Breaking current continuously adjustable,
max. 2x nominal current
ED at 2x nominal current 20%: 40 breakes/hour
Start contact potential free contact or
24V DC/10mA
Insulating strenght to power unit 2,5kV
Ambient temperature 0°C to +55°C
Storage temperature -25°C to +85°C
Protection class IP00
Ouput relay Motor/Alarm/Ready 4A/250V AC
Initiator (Option Lin-Br) NPN / PNP, 24V/12mA


Longer breaking times on request.

635.00 *
* Prices before VAT, plus delivery