SEIKOM-Electronic GmbH & Co. KG
The monitor NLSW45-3Ex is used with two Z-barriers (included in delivery) and flow sensors F3.*Ex.The flow sensors can be used as follows: In Zone 2 (Gas, Category 3G, EPL Gc) in the explosion groups IIA, IIB, and IIC. The qualification with regard to the surface temperature is T4; for all gases, vapours and mists with an ignition temperature > 135°C the equipment is not an ignition source. The requirements for simple electrical apparatus according to IEC60079-11, valid for the gas- hazardous area of Zone 1 are met. The NLSW45-3Ex must be installed outisde of the explosive area. Power consumption: 4VA Signal output flow: 1x changer Current and contact capacitance: 250VAC, 10A, 2.5kVA Media temperature: -10°C to +75°C Switch-point: adjustable with potentiometer Measurement range: approx. 0.1m/s to 20m/s Cabinet dimensions (LxWxB): 120mmx5mmx73mm Suitable sensors: F3Ex, F3.1Ex, F3.2Ex, F3.3Ex (not included in delivery) |
436.00 €
*
Delivery weight: 390 g
|
The flow sensors can be used as follows: In Zone 2 (Gas, Category 3G, EPL Gc) in the explosion groups IIA, IIB, and IIC. The qualification with regard to the surface temperature is T4; for all gases, vapours and mists with an ignition temperature > 135°C the equipment is not an ignition source. The requirements for simple electrical apparatus according to IEC60079-11, valid for the gas- hazardous area of Zone 1 are met. Media temperature: -25°C to +110°C (depends on the flow monitor) Immersion depth: 50mm Process connection: PG7 Sensor material: MS58, nickel-plated Pressure resistance: 10bar Temperature class: T4 Cable connection: 2.5m/3x0.5mm² Protection category: IP67 Suitable airflow monitors: NLSW45-3Ex |
257.00 €
*
Delivery weight: 210 g
|
The monitor is used with air-flow sensors F8Ex and two Z-barriers (included in delivery). It's able to watch flows of gaseous media in Zone 2 and temperature class T1. The NLSW45-6Ex must be installed outisde of the explosive area. Power consumption: 4VA Signal output flow: 1x changer Current and contact capacitance: 250VAC, 10A, 2.5kVA Media temperature: -20°C to +250°C Switch-point: adjustable with potentiometer Measurement range: approx. 0.1m/s to 20m/s Cabinet dimensions (LxWxB): 120mmx45mmx73mm Suitable sensors: F8Ex, F8.1Ex, F8.2Ex, F8.3Ex (not included in delivery!) |
439.00 €
*
Delivery weight: 350 g
|
Airflow sensor for gaseous media and Ex-areas, Zone 2 Temperature class: T1 Media temperature: -20°C to +250°C Immersion depth: approx. 50mm (alternatively 130/165/300 mm) Process connection: PG7 Sensor material: V2A stainless steel Pressure resistance: 10bar Cable connection: 2.5m/3x0.5mm² Protection class: IP50 Suitable airflow monitor: NLSW 45-6Ex Please regard the safety information contained in the manual! The image shows a F8.3Ex flow sensor (300mm immersion depth) |
274.00 €
*
Delivery weight: 210 g
|
Product no.: 60620/Ex
The flow monitor NLSW45-3Ex is used with two Z-barriers (included in delivery) and flow sensors F3.*Ex. Applicable range of the flow sensors: In Zone 2 (Gas, Category 3G, EPL Gc) in the explosion groups IIA, IIB, and IIC. Its unique feature is the analogue signal output. The qualification with regard to the surface temperature is T4; for all gases, vapours and mists with an ignition temperature >135°C the equipment does not present an ignition source. The requirements for simple electrical apparatus according to IEC60079-11, valid for the gas-hazardous area of Zone 1 are met. The NLSW75-AEx must be installed outside of the explosive area. Power consumption (max.): 5VA/W Signal output flow: 1x changer, 0 - 10 V and 4 - 20mA Current and contact capacitance: 250VAC, 6A, 1,5kVA Media temperature: 0°C to +60°C Switch-point: adjustable via potentiometer Measurement range: approx. 0.5m/s to 20m/s Cabinet dimensions (LxWxB): 112mmx75mmx73mm Suitable sensors: F3Ex, F3.1Ex, F3.2Ex, F3.3Ex (not included in delivery) |
548.00 €
*
Delivery weight: 650 g
|